Final Exam for Radon 202
Questions: 15
Time Limit: None
Total Attempts Allowed: Unlimited
0 of 15 questions completed
Questions:
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading…
You must sign in or sign up to start the quiz.
You must first complete the following:
0 of 15 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 point(s), (0)
Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)
A mitigation professional must review measurement results, including the site diagram provided by the measurement professional, to assist in developing an appropriate mitigation strategy.
According to the most recent Code revisions, New Residential Construction (420 ILCS 52) means any original construction of a single-family home or a dwelling containing 4 or fewer apartments, condominiums, or town houses.
According to the most recent Code revisions, the term “Passive New Construction Pipe” or “PNC” replaces the former definition of Passive New Construction System and Skeletal New Construction System.
A building contractor may activate a passive pipe installation should the buyer’s test yield a test result over 4.0 pCi/L.
“Radon Ready Construction” means the installation of passive new construction pipe during new residential construction. [420 ILCS 52].
A sump pit may not be used as the primary suction point for an active system except when the home has radiant heat lines installed in or below the floor.
A soil gas retarder of 10-mil or 3-mil cross-laminate polyethylene or equivalent is required over the gas permeable layer of the subfloor.
According to IEMA Mitigation Standards, which of the following statements is true?
The most effective radon reduction technique for a house built over a crawl space is:
Included in the annual report, a licensee must indicate what information?
According to the most recent Code revisions, which of the following choices is the passive radon New Residential Construction section added to the Code?
The requirements for section 422.160 are only mandatory in municipalities that have adopted the Radon Resistant Construction Act [420 ILCS 52.
Sub-Membrane Depressurization systems require the soil gas retarder to lap 12” up the crawlspace foundation walls and be permanently secured.
Which of the following are required in the labeling of an active radon mitigation system?
Radon mitigation specialists are not required to lower all radon levels below 4.0 pCi/L. ALARA allows for spaces that are extremely difficult, if not impossible to reduce below the action level.